| Customization: | Available |
|---|---|
| Theory: | Ethylene Oxide |
| Type: | Gas Sterilization Equipments |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The Sada Medical SADA-EO Ethylene Oxide Gas Sterilizer is a professional low-temperature sterilization solution engineered for hospitals, CSSD departments, cleanrooms, and clinics that process heat-sensitive, moisture-sensitive, and complex medical devices. Available in 80L, 120L, 220L, and 330L capacities, this Class II medical device delivers deep-penetration EO gas sterilization that reaches long tubes, thin cavities, and intricate instrument geometries that steam autoclaves and plasma sterilizers cannot effectively treat.
Built around a 304 anti-corrosion stainless steel chamber and a high-integrity 5052 aviation aluminum door (≥15mm thick, 200kPa rated), the SADA-EO ensures reliable sealing and durability through thousands of cycles. An oil-free vacuum pump rapidly achieves -60kPa for complete air removal before EO gas injection, while the fully automatic 5-stage process-Purge, Sterilization Hold (121°C, 15-20 min), Exhaust, and Drying-requires minimal operator intervention. The intuitive LCD touch display provides real-time monitoring of temperature, humidity, pressure, cycle time, residual gas treatment status, and steam generator temperature.
Safety is paramount: the integrated residual gas filtration system removes ≥99.5% of particles ≥0.2μm, and automatic air replacement cycles (5 times every 15 minutes) ventilate the chamber before access. Multiple alarms-over-voltage, over-temperature, ultra-low pressure-plus a power-off memory function protect both operators and instrument loads. Non-corrosive to instruments and safe for human implant devices, the SADA-EO meets the strictest sterilization requirements for modern healthcare facilities. CE certified and manufactured under ISO 9001 and ISO 13485 quality systems, it delivers the reliability, safety, and performance your sterilization workflow demands.
| Control system | PLC unit and 5 " touch screen |
| Sterilization chamber | SS304 stainless steel |
| Vacuum system | High-performance, low-noise, oil-free vacuum pump |
| Built-in printer | Thermal printer |
| Humidity system | Use saturated steam to humidify the sterilization chamber, and the air humidity is more uniform |
| Timing system | EO gas diffusion time and residual EO aeration timing settable |
| Pre-set | Standard Sterilization Mode and Residual Washing |
Hospital CSSD & Operating Rooms - sterilizing heat-sensitive surgical instruments, long-tube catheters, endoscopes, electronic devices, and complex lumened instruments
Human Implant Device Manufacturers - validated EO sterilization for implantable medical devices, orthopedic implants, cardiovascular stents, and surgical mesh
Pharmaceutical & Biotechnology Cleanrooms - sterilization of production tools, packaging components, and QC apparatus in GMP environments
Dental Clinics & Dental Hospitals - delicate handpieces, electronic dental instruments, and plastic components that cannot be steam sterilized
Veterinary Hospitals - heat-sensitive veterinary surgical tools, catheters, and implant devices
Medical Device Manufacturers - terminal sterilization of finished products, plastic components, and electronics before packaging
Ophthalmology Clinics - delicate ophthalmic instruments and diagnostic devices
Laboratories & Research Institutes - sensitive lab equipment, sensors, and plasticware requiring low-temperature sterilization
Superior Penetration for Complex Instruments: EO gas penetrates deep into long-tube objects, thin cavities, and complex lumened instruments-sterilizing areas that steam and plasma cannot reach, making it the gold standard for delicate, complex medical device sterilization.
Safe for Heat-Sensitive & Implant Devices: Operates at low temperature, making it ideal for human implant devices, electronics, plastics, and heat-sensitive surgical instruments that would be destroyed by steam autoclaves or damaged by hydrogen peroxide plasma.
99.5% Efficient Residual Gas Filtration (≥0.2μm): The integrated filtration system removes ≥99.5% of particles ≥0.2μm from exhaust gas, and combined with automatic air replacement (5 ventilation cycles every 15 minutes), ensures operator safety and environmental compliance after each cycle.
5052 Aviation Aluminum Door - 15mm Thick, 200kPa Rated: The sterilization door is crafted from high-grade 5052 aviation aluminum with ≥15mm thickness and 200kPa pressure resistance, delivering exceptional durability, superior sealing, and long-term structural integrity under repeated vacuum-pressure cycles.
Oil-Free Vacuum Pump - Reaches -60kPa in Under 30 Minutes: The powerful oil-free vacuum system eliminates oil mist contamination risks, rapidly achieving -60kPa for thorough air removal and consistent EO gas penetration-while reducing maintenance costs and downtime.
Real-Time LCD Touch Display with Full Cycle Visibility: The intuitive touch screen continuously monitors and displays operating status, chamber temperature, humidity, pressure, sterilization time, residual gas treatment time, and steam generator temperature-giving operators complete process oversight at a glance.
Power-Off Memory Function - No Data Loss, No Interruption: In the event of a power failure, the system saves all cycle data and current progress. When power is restored, sterilization resumes from the interruption point, protecting valuable instrument loads and preventing wasted cycles.
Multiple Independent Safety Systems: Equipped with over-voltage protection, over-temperature alarm, ultra-low pressure alarm, and automatic safety interlocks, the SADA-EO meets rigorous hospital safety protocols and protects both operators and instruments throughout every cycle.
304 Anti-Corrosion Stainless Steel Chamber: The chamber is constructed from 304 stainless steel, resisting the corrosive effects of ethylene oxide gas and humidity over years of daily use, ensuring long service life and easy cleaning.
Non-Corrosive to Instruments: Unlike some chemical sterilants, EO gas is non-corrosive and gentle on sterilized equipment, preserving the integrity, sharpness, and functionality of expensive surgical instruments and delicate implant devices.
Customizable Volume - 80L, 120L, 220L, 330L: Four chamber sizes accommodate different throughput requirements, from small clinics and dental practices (80L) to large hospital CSSD departments and medical device manufacturers (330L).
Full Automatic Cycle with 5-Stage Process: The sterilizer automates the complete cycle-Purge (air removal), Sterilization Hold (121°C, 15-20 min), Exhaust (gradual depressurization), and Drying (vacuum moisture removal)-ensuring consistent, validated sterilization with minimal operator intervention.
Sterilize What Others Cannot: Steam autoclaves destroy heat-sensitive instruments, and plasma sterilizers struggle with long lumens and complex geometries. The SADA-EO's deep gas penetration reaches every surface-inside thin catheters, complex endoscope channels, and implant device crevices-delivering validated sterilization where other methods fail.
Protect Your Most Valuable Instruments: Non-corrosive EO gas is gentle on expensive surgical tools, preserving sharp edges, delicate optics, and electronic components. For hospitals investing in advanced laparoscopic, robotic, and implantable devices, EO sterilization extends instrument life and protects capital investment.
Built with Premium Materials for Long-Term Reliability: The 5052 aviation aluminum door (15mm thick, 200kPa rated) and 304 stainless steel chamber are not standard in budget sterilizers. These materials ensure exceptional sealing, corrosion resistance, and structural integrity through years of daily hospital use.
Operator Safety Designed In, Not Added On: From the 99.5% efficient residual gas filtration and automatic 5-cycle ventilation to the oil-free vacuum pump and multiple independent alarms, every safety feature is integrated into the core design-protecting your staff and meeting the strictest hospital safety protocols.
No Data Loss, No Wasted Loads: The power-off memory function saves your cycle progress and instrument load when power fails. When electricity returns, sterilization resumes exactly where it stopped-critical for implant devices and expensive surgical sets that cannot be reprocessed unnecessarily.
Scalable Across Your Facility: With 80L to 330L options, you can standardize on the SADA-EO series across departments-small unit for the dental clinic, medium for outpatient surgery, large for central CSSD-with consistent operation, maintenance, and consumables.
2-Year Warranty, Global Support Network: Every SADA-EO is backed by a 2-year warranty, lifetime technical service, online support, and prompt spare parts availability. Our engineers respond within 24 hours to keep your sterilization workflow running.
Factory-Direct Value from an Experienced Manufacturer: Sada Medical exports steam autoclaves, plasma sterilizers, and EO sterilizers to healthcare providers worldwide. Buying direct means competitive pricing, customization options, and direct access to the team that engineers and builds your equipment.
| Model | SD-EO80 | SD-EO120 | SD-EO220 | SD-EO330 |
| Capacity | 80 Liter | 120 Liter | 220 Liter | 330 Liter |
| Sterilizing temperature | 36-55 C adjustable | |||
| Sterilizing Time | 8-10 Hours , depends on materials | |||
| Sterilization Method | Low temperature , gas sterilization . | |||
| Display | LCD screen , Soft touch operate key | |||
| Safety Features | Temperature and Pressure protection | |||
| Tray | 2 stainless net tray | |||
| Voltage | 220V, 50Hz | |||
| Data Review | Thermal mini-printer and USB port (download) | |||
| EO gas | 100% Pure EO gas cartridge | |||


1.What is your warranty for the products?
We offer 2 years warranty and lifetime service!
2.What is your after-sales service?
We provide technical support through operating manual and video; Once you have questions, you can get our engineer's prompt response by email,phone call,or training in factory. If it's hardware problem, within the warranty period, we will send you spare parts for free, or you send it back then we repair for you freely.
3.What is the delivery time?
We have shipping agent,we can deliver the products to you by express,air freight,sea.Below is some delivery time for your reference:
Express:UPS,DHL,TNT,ect (door to door),7-10 days
Hand carry:Send to your hotel,your friends,your forwarder,your sea port or your warehouse in China.
Air freigt(from airport to airport):3-10 days
Sea(any sea port):Mombasa(30 days), Port Kelang (12 days),Manila(10 days), Lagos(45 days), Guayaquil(45 days)
4.Can you customize?
Yes, Customized for Pannel, Voltage
5.How to place the order?
Send Proforma Invoice before order be placed, and arranging production after payment.
WHAT IS YOUR LEAD TIME OF THE PRODUCTS?
Portable type 5-10days, Table top and Vertical type 10-25days, Horizontal medium type 10-20days, Large type 30-35days
WHAT IS YOUR PAYMENT TERM?
Our payment term is Telegraphic Transfer in advance,Western union, MoneyGram,Paypal,ect.